IVS1000 Series Pure Sinewave DC / AC Inverters

BENEFITS

  • Ultra-Quiet
  • Power sensitive electronics without interference
  • Rugged & Reliable
  • Ensure years of safe and trouble free operation

The IVS1000 Series is a highly compact 1000VA DC/AC pure sinewave inverter that uses established design techniques to ensure high reliability.

Suitable for a wide range of applications, the IVS1000 features full electronic protection, high efficiency and low output noise. The built-in fan provides sufficient airflow for operation without de-rating up to 50°C ambient temperature. Extended operating temperature (-40 to +65°C) is available.

The inverter can be loaded with a fluorescent lamp load up to the full-specified output power.

Features

  • Input is filtered to EN 55022 Class A
  • Very low 60Hz input ripple current
  • Compact size, light weight
  • Sinusoidal wave shape
  • Multiple input and output voltages available
  • 1000VA of output power
  • Full electronic protection
  • Field-proven design topology
  • Also available as a frequency converter with 115VAC or 230VAC input
  • Applications

  • Marine / Automotive / RV
  • Electric Utilities and Substations
  • Telecom Power Plants
  • Manufacturing Locations
  • Steel Mills
  • Military Applications (COTS)
  • Industrial Controls
  • OEM Applications
  • Solar / Alternative Power Systems
  • Fuel Cells
  • Electrical [Input/Output]/ Mechanical Specification
    Input Voltage 24V, 36V, 48V, 125VDC, 250VDC +/-15% are standard
    Other inputs available, please consult factory
    Input Protection Thermal fuse, Inrush current limiting, Reverse polarity protection,
    Varistors, Lower voltage than specified input min. will not damage unit
    Isolation Input to chassis 500VDC for < 60V input, 1500VDC for > 60V input
    Input to output 2250VDC, Output to chassis 2250VDC
    Output Voltage 115VAC/60Hz or 400Hz @8.7A
    230V/50Hz @4.35A continuous with grounded neutral
    Isolated floating output optional (Consult factory for other voltages and frequencies)
    Wave Form Sinusoidal
    Total Harmonic Distortion Less than 5% at full load
    Efficiency Min. 76% at full load
    Line Regulation Max. 0.5%
    Load Regulation Maximum ± 6% from 10% load to full load
    ± 2% load regulation option available
    Output Protection Current limiting with short circuit protection, thermal shutdown with
    automatic recovery in case of continuous overload or insufficient airflow
    Output Overvoltage Protection 140/280 V by internal supply voltage limiting
    EMI Meets EN 55022 Class A as a minimum
    Load Crest Factor Maximum 2.5 at 90% load
    Output Noise High frequency ripple is better than 500m Vrms (20MHzBW)
    Operating Temperature Range 0 °C to +50°C
    Humidity 5 - 95% non-condensing
    Temperature Drift 0.05% per °C over operating temperature range
    Cooling Built-in fan drawing air into the unit
    Environmental Protection Basic ruggedizing
    Full ruggedizing and conformal coating as option
    Dimensions 7.5” x 5.3” x 15.5” (W x H x L) including terminal block and flanges
    Connections Input: Compression-type terminal / Output: Standard AC receptacle
    Weight 13.0 lb (5.9 kg)
    Safety Compliance to C22.2 No. 107.1 - 01 and UL 458 and EN60950
    Options Output Fail Alarm (Form C)
    Remote Inhibit: By closing external contacts on the inhibit terminals
    Warranty: Twenty-Four months subject to application within good engineering practice
    Enhancements to these general specifications can be accommodated upon request
    Designed to meet common approval requirements. Specifications Subject to Change Without Notice
    Designed and Manufactured in Canada
    TOP