IVS1500 Series Pure Sinewave DC / AC Inverters

BENEFITS

  • Ultra-Quiet
  • Power sensitive electronics without interference
  • Rugged & Reliable
  • Ensure years of safe and trouble free operation

The IVS1500 Series is a compact 1500VA DC/AC inverter that uses established design techniques to ensure high reliability.

Suitable for a wide range of applications, the IVS1500 features full electronic protection, high efficiency and low output noise. The built-in fan provides sufficient airflow for operation without de-rating up to 50°C ambient temperature.

The inverter can be loaded with a fluorescent lamp load up to the full-specified output power.

Features

  • Input is filtered to EN 55022 Class B
  • Very low 60Hz input ripple current
  • Modular design, light weight
  • Sinusoidal wave shape
  • Multiple input and output voltages available
  • 1500VA of output power
  • Full electronic protection
  • Field-proven design topology
  • Applications

  • Marine / Automotive / RV
  • Electric Utilities and Substations
  • Telecom Power Plants
  • Manufacturing Locations
  • Steel Mills
  • Military Applications (COTS)
  • Industrial Controls
  • OEM Applications
  • Solar / Alternative Power Systems
  • Fuel Cells
  • Electrical [Input/Output]/ Mechanical Specification
    Input Voltage 24V, 36V, 48V, 125V, 270VDC +/-20% are standard
    Other inputs available, please consult factory
    Input Protection Thermal fuse, Inrush current limiting, Reverse polarity protection
    Isolation Input to chassis 500VDC for < 60V input, 1500VDC for > 60V input
    Input to output 2250VDC, Output to chassis 2250VDC
    Output Voltage 115VAC / 13A or 230VAC / 6.5A continuous at 50, 60, or 400 Hz
    Isolated floating output optional
    Consult factory for other voltages and frequencies
    Wave Form Sinusoidal
    Total Harmonic Distortion Less than 5% at full load
    Efficiency Min. 78% at full load
    Line Regulation Max. 0.5%
    Load Regulation Maximum ± 6% from 10% load to full load
    (± 1% option available)
    Output Protection Current limiting with short circuit protection, thermal shutdown with
    automatic recovery in case of continuous overload or insufficient airflow
    EMI Meets EN 55022 Class B
    Load Crest Factor Maximum 3.0 at 90% load
    Operating Temperature Range 0 °C to +50°C Extended range available (Consult factory)
    Humidity 5 - 95% non-condensing
    Temperature Drift 0.05% per °C over operating temperature range
    Dimensions 5.3” X 13.8” x 16.75” (H x L x W) enclosed case
    Connections Input: Compression-type terminal / Output: Standard AC receptacle
    Weight 25.0 lb (11.35 kg)
    Safety Compliance to C22.2 No. 107.1 - 01 and UL 458
    Options Output Fail Alarm (Form C)
    Remote Inhibit: By connecting DC voltage (as specified) to the inhibit terminals
    Warranty: Twenty-Four months subject to application within good engineering practice
    Enhancements to these general specifications can be accommodated upon request
    Designed to meet common approval requirements. Specifications Subject to Change Without Notice
    Designed and Manufactured in Canada
    TOP