IVS200 Series Pure Sinewave DC / AC Inverters
- Ultra-Quiet
- Power sensitive electronics without interference
- Rugged & Reliable
- Ensure years of safe and trouble free operation

This rugged DC/AC inverter uses field proven, microprocessor controlled high frequency PWM technology to generate 200VA output power with pure sign wave output voltage. It is a mature design with a track record in numerous applications. The DC/DC input stage boosts the input voltage to a higher DC voltage, which feeds the DC/AC inverter to generate the required AC output. The use of high frequency conversion enables a compact construction, low weight and high efficiency. The unit has full electronic protection. The input and output are filtered for low noise. Cooling is via baseplate to a heatsinking surface and by natural convection. The use of components with established reliability results in high MTBF. The unit is manufactured at our plant under strict quality control.
Features
Applications
- Marine / Automotive / RV
- Electric Utilities and Substations
- Telecom Power Plants
- Manufacturing Locations
- Steel Mills
- Military Applications (COTS)
- Industrial Controls
- OEM Applications
- Solar / Alternative Power Systems
- Fuel Cells
| Input Voltage | 24V, 36V, 48V, 125VDC +/-15% are standard Other inputs available, please consult factory |
|---|---|
| Input Protection | Thermal fuse, Inrush current limiting, Reverse polarity protection, Varistors, Lower voltage than specified input min. will not damage unit |
| Isolation | Input to chassis 500VDC for < 60V input / 1500 VDC for > 60V input Input to output 2250VDC / Output to chassis 2250VDC |
| Output Voltage | 115VAC / 60Hz or 400Hz @ 1.7A continuous or 230VAC/50Hz @ 0.86 continuous with isolated floating output optional |
| Wave Form | Sinusoidal |
| Total Harmonic Distortion | Less than 5% at full load |
| Efficiency | Input voltage dependent. 80% at full load |
| Line Regulation | Max. ± 0.5% |
| Load Regulation | Max. ± 3% from no load to full load |
| Output Protection | Current limiting with short circuit protection; Thermal shutdown with automatic recovery in case of continuous overload or insufficient cooling |
| Output Overvoltage Protection | 140/280 V by internal supply voltage limiting |
| EMI | Meets EN 55022 Class A as a minimum |
| Load Crest Factor | Maximum 3.0 at 90% load |
| Output Noise | High frequency ripple is better than 500m Vrms (20MHzBW) |
| Operating Temperature Range | 0 °C to +50°C. Extended temperature ranges available |
| Humidity | 5 - 95% non-condensing |
| Temperature Drift | 0.05% per °C over operating temperature range |
| Cooling | Conduction/convection (no fan) |
| Environmental Protection | Basic ruggedizing |
| Dimensions | 5.2” x 2.5” x 11.4” (W x H x L) including terminal block and flanges |
| Connections | 12-pole barrier-type terminal block with 3/8” spacing |
| Weight | 4.4 lb (2.0kg) |
| Safety | Compliance to C22.2 No. 107.1 - 01 and UL 458 and EN60950 |
| Options | Output Fail Alarm (Form C) Remote Inhibit: By closing external contacts on the inhibit terminals |
| Warranty: Twenty – Four months subject to application within good engineering practice Enhancements to these general specifications can be accommodated upon request Designed to meet common approval requirements. Specifications Subject to Change Without Notice Designed and Manufactured in Canada |
|