LVS1000 Series Sinewave Telecom DC / AC Inverters

BENEFITS

  • Ultra-Quiet
  • Power sensitive electronics without interference
  • Rugged & Reliable
  • Ensure years of safe and trouble free operation

The LVS1000 Series compact DC/AC Inverter utilizes established design techniques to ensure high reliability

Suitable for a wide range of applications, the LVS1000 features full electronic protection, high efficiency and low output noise.

The built-in fan provides sufficient airflow for operation without de-rating up to 50oC ambient temperature. Extended operating temperature (-40 to +65°C) is available.

The inverter can be loaded with a fluorescent lamp load up to the full specified output power.

Features

  • Low profile, compact size, light weight
  • Input is filtered to EN 55022 Class B (typical)
  • Sinusoidal wave shape
  • 1000VA of output power
  • Full electronic protection
  • Field-proven design topology
  • Applications

  • Marine / Automotive / RV
  • Electric Utilities and Substations
  • Telecom Power Plants
  • Manufacturing Locations
  • Steel Mills
  • Military Applications (COTS)
  • Industrial Controls
  • OEM Applications
  • Solar / Alternative Power Systems
  • Fuel Cells
  • Electrical [Input/Output]/ Mechanical Specification
    Input Voltage 24V, 36V, 48V, 125V, 250VDC +/-20% are standard
    Other input voltages available
    Input Protection Thermal fuse, Inrush current limiting, Reverse polarity protection
    Isolation Input to chassis: 1500VDC/ Input to output: 3000VDC/ Output to chassis : 2250VDC
    Output Voltage 115VAC / 8.7A continuous or 230VAC / 4.34A continuous at 50, 60 or 400Hz with grounded neutral
    Isolated floating output optional / Other outputs available
    Wave Form Sinusoidal
    Total Harmonic Distortion Less than 5% at full load
    Efficiency Min. 78% at full load
    Line Regulation Max. 0.5%
    Load Regulation Maximum ± 2% from 10% load to full load
    Output Protection Current limiting with short circuit protection, thermal shutdown with
    automatic recovery in case of continuous overload or insufficient airflow
    EMI EN 55022 Class B (typical)
    Load Crest Factor Maximum 3.0 at 90% load
    Operating Temperature Range 0 °C to +50°C
    Humidity 5 - 95% non-condensing
    Temperature Drift 0.05% per °C over operating temperature range
    Dimensions 2.64” x 19” x 13.97” enclosed case (H x W x L)
    Connections Input: Compression-type terminal / Output: Standard AC receptacle
    Weight 17.6 lb (8.0 kg)
    Safety Designed to meet C22.2 No. 107.1 - 01, UL 458 and EN60950
    Options Output Fail Alarm (Form C)
    Remote Inhibit: By connecting DC voltage (as specified) to the inhibit terminals
    Warranty: Twenty-Four months subject to application within good engineering practice
    Enhancements to these general specifications can be accommodated upon request
    Designed to meet common approval requirements. Specifications Subject to Change Without Notice
    Designed and Manufactured in Canada